Related Experiment Video
Updated: Dec 15, 2025

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Obtaining PET/CT images from non-attenuation corrected PET images in a single PET system using Wasserstein generative
Zhanli Hu1,2, Yongchang Li1,3,2, Sijuan Zou4
1Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055 People's Republic of China.
Abstract:
Positron emission tomography (PET) imaging plays an indispensable role in early disease detection and postoperative patient staging diagnosis. However, PET imaging requires not only additional computed tomography (CT) imaging to provide detailed anatomical information but also attenuation correction (AC) maps calculated from CT images for precise PET quantification, which inevitably demands that patients undergo additional doses of ionizing radiation. To reduce the radiation dose and simultaneously obtain high-quality PET/CT images, in this work, we present an alternative based on deep learning that can estimate synthetic attenuation corrected PET (sAC PET) and synthetic CT (sCT) images from non-attenuation corrected PET (NAC PET) scans for whole-body PET/CT imaging. Our model consists of two stages: the first stage removes noise and artefacts in the NAC PET images to generate sAC PET images, and the second stage synthesizes CT images from the sAC PET images obtained in the first stage. Both stages employ the same deep Wasserstein generative adversarial network and identical loss functions, which encourage the proposed model to generate more realistic and satisfying output images. To evaluate the performance of the proposed algorithm, we conducted a comprehensive study on a total of 45 sets of paired PET/CT images of clinical patients. The final experimental results demonstrated that both the generated sAC PET and sCT images showed great similarity to true AC PET and true CT images based on both qualitative and quantitative analyses. These results also indicate that in the future, our proposed algorithm has tremendous potential for reducing the need for additional anatomic imaging in hybrid PET/CT systems or the need for lengthy MR sequence acquisition in hybrid PET/MRI systems.
More Related Videos
07:45Author Spotlight: Standardizing Mouse In Vivo PET Imaging with Body Conforming Molds and Automated Analysis
Published on: October 25, 2024
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024