High κ free light chain is a potential biomarker for double seronegative and ocular myasthenia gravis
Adi Wilf-Yarkoni1, Yifat Alkalay1, Talma Brenner1
1From the Neuroimmunology and Multiple Sclerosis Unit of the Neurology Division (A.W.-Y., A.K.), Tel Aviv Sourasky Medical Center; Clinical Immunology Laboratory (Y.A.), Tel Aviv Sourasky Medical Center; Laboratory of Neuroimmunology (T.B.), Department of Neurology, the Agnes Ginges Center for Human Neurogenetics, Hadassah-Hebrew University Medical Center, Jerusalem; Sackler Faculty of Medicine (A.K.), Tel Aviv University; and Sagol School of Neuroscience (A.K.), Tel Aviv University, Israel.
Objective:
To investigate the hypothesis that free light chain (FLC) sera levels could serve as a biomarker for myasthenia gravis (MG), especially for the subgroups of seronegative MG and ocular MG.
Methods:
Sera from 73 patients with MG (20 seronegative for antiacetylcholine receptor [AChR] and anti-muscle-specific kinase and 53 positive for anti-AChR, which were clinically divided into 24 patients with ocular type, 45 with generalized type, and 4 with unequivocal clinical manifestation) and 49 healthy controls were studied for κ FLC and λ FLC levels with the Freelite human FLC kits.
Results:
The κ but not the λ levels of FLC were significantly increased in the patients with MG, including those with double seronegative MG and ocular MG, compared with the healthy controls. The specificity for double seronegative MG and ocular MG were both 98.0% when κ FLC was ≥25.0 mg/L. Increased κ FLC levels were not affected by the patient's sex, age at MG onset, the presence of thymic pathology, or different treatments.
Conclusions:
Elevated serum κ FLC may serve as a biomarker for MG in suspected patients who are double seronegative and in those with only ocular manifestations when serology is inconclusive.
Classification Of Evidence:
This study provides Class III evidence that high κ FLC levels distinguished patients with MG, including those who were double seronegative, from healthy controls.
More Related Videos
10:19High-throughput Flow Cytometry Cell-based Assay to Detect Antibodies to N-Methyl-D-aspartate Receptor or Dopamine-2 Receptor in Human Serum
Published on: November 23, 2013
13:21Chemically-blocked Antibody Microarray for Multiplexed High-throughput Profiling of Specific Protein Glycosylation in Complex Samples
Published on: May 4, 2012
Related Concept Videos
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Myasthenia Gravis: Overview and Treatment
These antibodies interfere with the function of the nicotinic receptors in three ways: by binding to the receptor and disrupting acetylcholine binding; by causing cross-linking of receptors which...