A novel method for measuring absolute coronary blood flow and microvascular resistance in patients with ischaemic

Paul D Morris1,2,3, Rebecca Gosling1,2,3, Iwona Zwierzak1,3

  • 1Mathematical Modelling in Medicine Group, Department of Infection, Immunity and Cardiovascular Disease, Medical School, University of Sheffield, Sheffield , UK.

Insights

A new computational fluid dynamics (CFD) method accurately measures absolute coronary blood flow and microvascular resistance (MVR) in the catheter lab, improving diagnosis of ischaemic heart disease.

Area of Science:

  • Cardiovascular Physiology
  • Medical Imaging
  • Computational Fluid Dynamics

Background:

  • Ischaemic heart disease involves reduced myocardial blood flow due to epicardial or microvascular issues.
  • Current assessment using Fractional Flow Reserve (FFR) is limited, assessing only percentage flow changes and not absolute flow or microvascular disease.
  • Distinct management strategies exist for epicardial and microvascular coronary disease.

Purpose of the Study:

  • To develop and validate a novel computational fluid dynamics (CFD) model for predicting absolute coronary blood flow and microvascular resistance (MVR).
  • To enable comprehensive physiological assessment within the catheter laboratory setting.
  • To differentiate and quantify both epicardial and microvascular coronary artery disease.

Main Methods:

  • A CFD model was developed to predict absolute coronary flow (QCFD) and MVR using routine invasive angiography and pressure-wire data.
  • The QCFD model was validated using an in vitro flow circuit with patient-specific 3D-printed coronary arteries.
  • In vivo validation was performed in 40 patients with coronary disease, assessing QCFD and MVR under baseline and hyperaemic conditions.

Main Results:

  • In vitro validation showed close agreement between QCFD and experimental flow (R² = 0.999).
  • In vivo, QCFD and MVR were successfully computed in all patients, enabling calculation of coronary flow reserve (CFR).
  • QCFD-derived CFR strongly correlated with pressure-derived CFR (R² = 0.92), and the method proved significantly more accurate than Doppler-wire flow.

Conclusions:

  • Absolute coronary flow and MVR can be determined non-invasively during routine catheter laboratory procedures.
  • This novel method allows for the discrimination and quantification of both epicardial and microvascular coronary artery disease.
  • Comprehensive coronary physiological assessment using this technique may enhance patient stratification and management.