Related Experiment Video
Updated: Dec 14, 2025

Multiplexed Immunofluorescence Analysis and Quantification of Intratumoral PD-1+ Tim-3+ CD8+ T Cells
Published on: February 8, 2018
Immunoaffinity microflow liquid chromatography/tandem mass spectrometry for the quantitation of PD1 and PD-L1 in
Yongxin Zhu1, Jacob Zalaznick1, Bogdan Sleczka1
1Research and Development, Bristol-Myers Squibb Company, Princeton, NJ, USA.
Rationale:
High tumor expression of programmed cell death protein (PD1) and programmed death-ligand 1 (PD-L1) is thought to be associated with positive clinical outcomes after treatment with anti-PD1 or anti-PD-L1 agents. Several sensitive methods based on immunohistochemistry, ligand binding assay (LBA), and liquid chromatography/mass spectrometry involving the measurement of PD1 and PD-L1 expression have been reported. Here, we expand on the characterization of different tumor types using a highly specific, sensitive, and robust immunoaffinity liquid chromatography/tandem mass spectrometry (IA-LC/MS/MS)-based method for the simultaneous quantitation of PD1 and PD-L1 in tumor tissues.
Methods:
Human tumor tissue samples were homogenized using a Precellys Evolution homogenizer. The samples were incubated with anti-PD1 and anti-PD-L1 capture polyclonal antibodies, which were bound to magnetic beads. Following enrichment, samples were digested with trypsin. A Waters iKEY HSS T3 1.8 um (150 μm × 100 mm) column with a gradient flow rate of 3 μL/min was used for chromatographic separation, and a Waters TQ-S triple quadrupole mass spectrometer was used for detection. Selected reaction monitoring (SRM) transitions with unit resolution for precursor/product ion masses were optimized for PD1 and PD-L1 surrogate peptides.
Results:
The surrogate peptides LAAFPEDR for PD1 and FTVTVPK for PD-L1 yielded the most intense SRM transitions at m/z 459.7 > 516.2 and m/z 396.2 > 543.3, respectively, and thus were selected for the quantitation of PD1 and PD-L1. The lower limit of quantitation for PD1 and PD-L1 was 0.062 ng/mL with an assay range up to 10 ng/mL. Using this method, human PD1 and PD-L1 were detected and quantified from four different types of tumor tissues. The data show that PD1 expression level was highly correlated with that of PD-L1 in all tumor tissues analyzed here.
Conclusions:
A highly specific and sensitive immunoaffinity microflow LC/MS/MS method for the simultaneous quantification of PD1 and PD-L1 in tumor tissues was developed and implemented. This method combines the advantage of immuno-capture for analyte enrichment with the high specificity of detection of multiple surrogate peptides by LC/MS/MS. The quantification of PD1 and PD-L1 co-expression in tumor could help evaluate their role in assessing tumor type selection and patient stratification.