Screening lengths and osmotic compressibility of flexible polyelectrolytes in excess salt solutions

Carlos G Lopez1, Ferenc Horkay, Matan Mussel

  • 1Institute of Physical Chemistry, RWTH Aachen University, Landoltweg 2, 52056 Aachen, Germany. lopez@pc.rwth-aachen.de.

Soft Matter
|July 16, 2020
PubMed

Related Concept Videos

Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
1.4K
Osmosis and Osmotic Pressure of Solutions02:40

Osmosis and Osmotic Pressure of Solutions

A number of natural and synthetic materials exhibit selective permeation, meaning that only molecules or ions of a certain size, shape, polarity, charge, and so forth, are capable of passing through (permeating) the material. Biological cell membranes provide elegant examples of selective permeation in nature, while dialysis tubing used to remove metabolic wastes from blood is a more simplistic technological example. Regardless of how they may be fabricated, these materials are generally...
45.2K
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
876
Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
1.0K
SDS-PAGE01:27

SDS-PAGE

Gel electrophoresis is a method that separates biological macromolecules like nucleic acids or proteins by forcing them to pass through a gel matrix under an electric field.
A variation of gel electrophoresis, termed  polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
32.3K
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
1.4K