Prototype system for interventional dual-energy subtraction angiography
Michael A Speidel1,2, Christiane S Burton3, Ethan P Nikolau1
1Dept. of Medical Physics, Univ. of Wisconsin - Madison, Madison, WI, USA.
Abstract:
Dual-energy subtraction angiography (DESA) using fast kV switching has received attention for its potential to reduce misregistration artifacts in thoracic and abdominal imaging where patient motion is difficult to control; however, commercial interventional solutions are not currently available. The purpose of this work was to adapt an x-ray angiography system for 2D and 3D DESA. The platform for the dual-energy prototype was a commercially available x-ray angiography system with a flat panel detector and an 80 kW x-ray tube. Fast kV switching was implemented using custom x-ray tube control software that follows a user-defined switching program during a rotational acquisition. Measurements made with a high temporal resolution kV meter were used to calibrate the relationship between the requested and achieved kV and pulse width. To enable practical 2D and 3D imaging experiments, an automatic exposure control algorithm was developed to estimate patient thickness and select a dual-energy switching technique (kV and ms switching) that delivers a user-specified task CNR at the minimum air kerma to the interventional reference point. An XCAT-based simulation study conducted to evaluate low and high energy image registration for the scenario of 30-60 frame/s pulmonary angiography with respiratory motion found normalized RMSE values ranging from 0.16% to 1.06% in tissue-subtracted DESA images, depending on respiratory phase and frame rate. Initial imaging in a porcine model with a 60 kV, 10 ms, 325 mA / 120 kV, 3.2 ms, 325 mA switching technique demonstrated an ability to form tissue-subtracted images from a single contrast-enhanced acquisition.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...