Related Experiment Video
Updated: Dec 14, 2025

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Senior interventional cardiologists are exposed to higher effective doses than other staff members
H A Abdel Ghany1, H M Diab2, Asmaa Salah2
1Department of Physics, Faculty of Women for Arts, Science and Education, Ain-Shams University, Cairo, Egypt. hayam168@yahoo.com.
Abstract:
Those working in interventional cardiology are exposed to varying radiation doses during diagnostic and interventional procedures. The work presented in this paper aimed to monitor the effective doses received by different categories of medical staff members practicing interventional cardiology procedures including senior cardiologists, junior cardiologists, anesthetists and nurses. Thermo-luminescence dosimeter (TLD) badges that consisted of lithium fluoride doped with magnesium and titanium were used to quantify radiation doses. Measurements were performed with the dosimeters mounted under and above leaded aprons worn by medical staff. The results revealed that the effective doses to senior cardiologists were the highest compared to those to other participating staff members, due to their position close to the X-ray tube. The average daily effective doses for senior cardiologists, junior cardiologists, anesthetists and nurses were higher for dosimeters located above the aprons than those for dosimeters located under the aprons. Above the apron, the average effective doses accumulated during the study period were 0.44 ± 0.06, 0.34 ± 0.05, 0.29 ± 0.03 and 0.29 ± 0.04 mSv, respectively; whereas, under the apron, they were 0.20 ± 0.02, 0.18 ± 0.02, 0.17 ± 0.02 and 0.18 ± 0.02, respectively. Also, the fluoroscopy time was correlated with the dose acquired, especially for senior cardiologists. It is concluded that doses to senior cardiologists are quite high, and that many variables can affect staff exposure such as distance, direction, procedure and skills.
More Related Videos
08:30X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Cardiac Catheterization IV: Nursing Management