Related Experiment Video
Updated: Dec 14, 2025

Generation of Hypoparathyroid Rats via Carbon-Nanoparticle-Assisted Parathyroidectomy
Published on: July 14, 2023
18F-fluorocholine PET/CT in MEN1 Patients with Primary Hyperparathyroidism
Mathieu Gauthé1,2, Anne Dierick-Gallet3, Thierry Delbot4
1Department of Nuclear Medicine, Hôpital Tenon, Assistance Publique-Hôpitaux de Paris, Sorbonne Université, Paris, France.
Background:
Primary hyperparathyroidism (HPT1) is the most frequent endocrinopathy in multiple endocrine neoplasia type 1 (MEN1). Its surgical management is challenging. We aimed to describe and compare the imaging findings of parathyroid ultrasound (US), sestaMIBI scintigraphy (sestaMIBI), and 18F-fluorocholine (FCH) PET/CT in a series of MEN1 patients with HPT1.
Methods:
Retrospective analysis of a cohort of MEN1 patients with HPT1 assessed by parathyroid US, sestaMIBI scintigraphy and SPECT/CT, and FCH-PET/CT for potential surgery between 2015 and 2019.
Results:
Twenty-two patients with a confirmed diagnosis of MEN1 who presented with HPT1 and were assessed by the 3 imaging modalities were included. After imaging workups, 11 patients were operated on for the first time, 4 underwent a redo surgery, and 7 did not undergo an operation. The overall patient-based positivity rate of imaging was 91% (20 of 22) for parathyroid US and 96% (21 of 22) for both sestaMIBI and FCH-PET/CT. The 3 imaging modalities demonstrated negative findings in 1/22 patient who did not undergo surgery. Overall, 3 pathologic glands were not detected by any imaging technique. SestaMIBI and FCH-PET/CT both resulted in the same 3 false-positive results in ectopic areas with a significant uptake on two thymic carcinoid tumors and one inflammatory lymph node. FCH-PET/CT provided more surgically relevant data than sestaMIBI in 4/11 patients with initial surgery and in 1/4 patient who underwent redo surgery.
Conclusions:
Compared to sestaMIBI scintigraphy, FCH-PET/CT provides additional information regarding the number of pathologic parathyroid glands and their localization in MEN1 patients with HPT1.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
10:20Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT