Impregnation of healthy nail tissue with optical clearing agents for improved optical coherence tomography imaging
Vinzent Kevin Ortner1, Victor Desmond Mandel2,3, Merete Haedersdal1
1Department of Dermatology and Wound Healing Centre, Copenhagen University Hospital, Bispebjerg and Frederiksberg, Copenhagen, Denmark.
Objectives:
The impact of optical tissue clearing on optical coherence tomography (OCT) for nail tissue imaging has not been investigated. This study seeks to compare the effects of an emollient and water on visualization of micromorphology and morphometric outcomes.
Materials And Methods:
Thirty-six healthy nail plates were processed with a fractional CO2 laser, imaged with OCT, and measured with calipers in duplicates. All samples were reassessed after 12-hour long sequential immersion in water and an emollient (Crodamol™ STS). OCT images were evaluated for thickness and scattering signal of the nail.
Results:
Emollient-impregnation caused stronger scatter responses (P < .0001) and decreased nail thickness (MD 45 μm, P < .0001) measured on OCT. Caliper-derived measurements were not affected by Crodamol™ (MD 11 μm, P = .5538). Hydration increased nail thickness on OCT (MD 49 μm, P < .0001) but reduced thickness measurements taken with calipers (MD 41 μm, P < .0001). Emollient-impregnation improved visualization of onychocytes compared with dry (P = .0209) and hydrated samples (P < .0001), and reduced occurrence of refractive artifacts (P < .0001).
Conclusion:
The use of an emollient for OCT imaging can enhance nail tissue visualization without significant effects on caliper measurements. Hydration of nails, in contrast with emollient-impregnation, may lead to disagreement between caliper- and OCT-measured nail thickness and should be practiced cautiously.
More Related Videos
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...