Related Experiment Video
Updated: Dec 14, 2025

The Calibration and Use of Capacitance Sensors to Monitor Stem Water Content in Trees
Published on: December 27, 2017
Unravelling the relationship between stem temperature and air temperature to correct for errors in sap-flow
Kathy Steppe1, Raoul Lemeur1, Diego Dierick1
1Department of Applied Ecology and Environmental Biology, Laboratory of Plant Ecology, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium.
Abstract:
Results from measurement of sap flow by heat balance sensors on the stem of a young oak tree (Quercus robur L.) revealed that thermal disequilibrium (i.e. heat storage) within the heated stem segment can introduce considerable errors in the measured sap-flow rates. The magnitude, sign and significance of these errors depend on the sap-flow rate and on the relationship between stem temperature and air temperature. Sap-flow rates were found to be more prone to errors caused by heat storage effects under low flow conditions than at higher rates of sap flow. Furthermore, daytime fluctuations of air temperature and stem temperature inside the heat balance sensor were either in phase when a low, or in opposite phase when a high sap-flow rate was passing through the stem of the young tree. To investigate this relationship, we developed an experimental set-up with cut stem segments through which tap water could be pressed. This set-up allowed the effects of air temperature and sap-flow rates on stem temperatures within heat balance sensors to be clearly separated. Good mathematical relationships were obtained and were successfully used to assess the relative importance of air temperature and sap-flow rate with respect to the fluctuations in stem temperature of the young oak tree. Based on the established relationships, a novel approach was put forward to correct for errors introduced into sap-flow calculations caused by heat storage effects if no measured data on stem temperature are available.
More Related Videos
08:49Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
09:55Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
Published on: December 12, 2013
Related Concept Videos
Responses to Heat and Cold Stress
Distance Corrections
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Regulation of Transpiration by Stomata
Pipe Flowrate Measurement: Problem Solving