Related Experiment Video
Updated: Dec 14, 2025

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Alternate reversed-phase and hydrophilic interaction liquid chromatography coupled with mass spectrometry for broad
Wangjie Lv1, Lei Guo2, Fujian Zheng1
1CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China; University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
Because of the greatly different physicochemical properties of metabolites, comprehensive metabolite profiling analysis has always been a challenging task. Reversed-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC) have been used to the analysis of nonpolar metabolites and polar metabolites, respectively. In this work, an alternate HILIC/RPLC-mass spectrometry (MS) approach was developed for the comprehensive and high-throughput analysis of polar and nonpolar metabolites. HILIC and RPLC are respectively performed on two ultra-high performance LC (UHPLC) systems, and coupled to one mass spectrometer to acquire the data. When HILIC gradient elution is running RPLC is in a washing and equilibration state, and vice versa. As a result, the total analysis time was reduced by about one third to 25.4 min. Two hundred and eight representative standards including at least twelve types of commonly met metabolites, SRM 1950 plasma, serum, urine and liver tissue samples were used to test the established alternate HILIC/RPLC-MS method. The results demonstrated that the method possessed high metabolite coverage. The developed method was validated to have good linearity and repeatability. As an example of application, 61 significantly changed metabolites in the colon cancer tissues were defined by this established method.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: