Related Experiment Video
Updated: Dec 14, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Clinical outcomes with a new design in multifocal intraocular lens: a pilot study
Jorge L Alió1,2, Pilar Yébana1, Mario Cantó1
1Vissum Corporation, Avda de Denia s/n, Edificio Vissum, 03016 Alicante, Spain.
Purpose:
To evaluate the clinical and visual outcomes, quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens (IOL).
Methods:
In this prospective consecutive case series, 20 eyes of 10 patients were included (mean age 63.80 ± 12.55 years). Uncorrected and corrected visual acuity (far, intermediate and near), subjective refraction, binocular defocus curve, contrast sensitivity (CSV-1000) and quality of vision and satisfaction questionnaires were measured. The follow-up was 12 months after surgery.
Results:
At 12 months after surgery, uncorrected distance visual acuity (UDVA) improved with surgery (p = 0.001) with a value of 0.08 ± 0.08 logMAR. Uncorrected near visual acuity (UNVA) was 0.22 ± 0.12 logMAR and distance corrected near visual acuity (DCNVA) was 0.16 ± 0.13 logMAR. Intermediate distance visual acuity (UIVA) was 0.22 ± 0.10 logMAR. Contrast sensitivity outcomes were similar to normal population in photopic conditions and slightly reduced in mesopic conditions of lighting. Defocus curve showed that this multifocal IOL was able to provide a visual acuity (VA) equal or better to 0.16 logMAR between defocus levels of + 1.00 to - 2.50 D. Good patient satisfaction was obtained in quality of vision and satisfaction questionnaires outcomes.
Conclusions:
The Precizon Presbyopic NVA IOL (OPHTEC BV) provides good visual outcomes. This multifocal IOL provides a high percentage of spectacle independence due to good VA at far, intermediate and near distances and satisfactory contrast sensitivity. High patient satisfaction was observed in quality of vision and satisfaction questionnaires with a low percentage of patients manifesting photic phenomena.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Glaucoma: Overview