Biomechanical behavior of three different types of internal tapered connections after cyclic and static loading
Marcos Boaventura de Moura1, Karine Regina Tolesano Loureiro2, Livia Bonjardim Lima2
1Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlandia, Av. Pará 1720, Bloco 4LB, sala 39, Uberlandia, MG, 38405-902, Brazil. boaventura.mm@hotmail.com.
Background:
In the long-term success of a dental implant, the reliability and stability of the implant-abutment interface are important. Studies of maximum force of dental implants with different loading values have been used. This study aims to evaluate the influence of the oblique cyclic loading on the maximum force supported in one-piece and two-piece abutments installed on internal tapered implants.
Findings:
Sixty implants and sixty prosthetic abutments were divided into six groups (n = 10): G1 and G2 (two-piece abutments with 16°), G3 and G4 (two-piece abutments with 11.5°), and G5 and G6 (one-piece abutments with 11.5°). A 2-Hz cyclic loading was applied to specimens of G2, G4, and G6, with a number of cycles of 2,400,000. All specimens were inclined by 30° from the vertical axis, and a vertical loading was applied over the tapered connections (ISO 14801). Then, the maximum force was tested by applying a static compression load on the specimens of the 6 groups tested (30°) at a rate of 0.5 mm/s. Statistical analysis was performed using the Shapiro-Wilk (p > 0.05) and Levene (p = 0.789) tests to determine if the data presented homoscedasticity and the Tukey test for multiple comparisons. Tukey test showed that the maximum force supported by G1 and G2 was not affected by the cyclic load, while in G3 and G4 it decreased significantly when subjected to the cyclic load. The G5 and G6 had a significant increase in maximum force supported when subjected to cyclic load.
Conclusions:
Cyclic loading influenced the maximum force supported of G4 and G6 but did not influence G2.
More Related Videos
Related Concept Videos
Normal Strain under Axial Loading
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Thin-Walled Hollow Shafts
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Residual Stresses in Circular Shafts