Delayed bolus-tracking trigger at CT correlates with cardiac dysfunction and suboptimal portovenous contrast phase
Corey T Jensen1, Rahul Khetan2, Jake Adkins2
1Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA. cjensen@mdanderson.org.
Insights
Delayed bolus-tracking trigger times in CT scans correlate with reduced heart function and suboptimal portovenous contrast phases. This finding suggests potential cardiac dysfunction impacting imaging quality.
Area of Science:
- Radiology
- Cardiology
- Medical Imaging
Background:
- Bolus-tracking is a common technique for optimizing contrast enhancement in CT scans.
- Cardiac function can influence circulatory dynamics, potentially affecting contrast delivery and timing.
Purpose of the Study:
- To investigate the association between delayed bolus trigger times during CT scans and indicators of reduced heart function.
- To determine if delayed trigger times correlate with suboptimal portovenous contrast phases in abdominal CT.
Main Methods:
- Retrospective analysis of 114 patients undergoing abdominal CT with bolus-tracking and recent echocardiography.
- Recorded bolus trigger time (BTT), ejection fraction, congestive heart failure (CHF) history, and age.
- Assessed liver contrast phase using a 1-5 scoring system; analyzed correlations using simple linear regression.
Main Results:
- A longer BTT significantly correlated with reduced ejection fraction (P=0.0018) and lower hepatic contrast scores (P<0.0001).
- Delayed trigger times were also associated with CHF history (P=0.0212) and older age (P=0.0223).
- Lower ejection fraction was a significant predictor of suboptimal portovenous contrast phase (P<0.0001).
Conclusions:
- Delayed bolus trigger times in CT may indicate underlying cardiac dysfunction.
- These delays can lead to inadequate contrast enhancement for optimal portovenous phase imaging.
- Assessing BTT in conjunction with cardiac function may improve CT imaging protocols.
Objective:
To assess whether delayed trigger during bolus-tracking for CT correlates with reduced heart function and suboptimal portovenous contrast phase.
Methods And Materials:
Patients who underwent portovenous abdominal CT using bolus-tracking and echocardiography within 2 weeks were included and excluded if there was a non-standard contrast injection. The bolus trigger time (BTT) at 100 Hounsfield units in the abdominal aorta, patient age, congestive heart failure (CHF) history, and ejection fraction were recorded. Two radiologists scored the liver contrast phase (1-5, 5 being an optimal portovenous phase). When applicable, the BTT and contrast score of the most recent comparison examination with equivalent technical parameters were also recorded. Simple linear regression (univariate) was used to test for associations with trigger time.
Results:
114 patients with a mean age of 61 ± 15 years fulfilled criteria. The mean trigger time was 18 ± 6 s (range: 6-38 s) and the mean ejection fraction was 52 ± 12% (range: 19-69%). A longer bolus trigger had a significant correlation with reduced ejection fraction (P = 0.0018), lower hepatic contrast score (P < 0.0001), history of CHF (P = 0.0212), and older age (P = 0.0223). Contrast score differences between the study exam and available prior exams revealed score differences of 0 (n = 73), 1 (n = 15) and 2 (n = 5); these were associated, respectively, with a mean bolus trigger time difference between exams of 2 s (range, 0-6 s), 6 s (range, 1-15 s), and 11 s (range, 5-13). The P-value comparing bolus trigger time and contrast score differences was less than 0.0001. A lower ejection fraction also significantly correlated with suboptimal PV contrast phase (P < 0.0001).
Conclusion:
Delayed time to trigger during bolus-tracking for CT can indicate cardiac dysfunction and may not adequately adjust to provide an optimal portovenous contrast phase.