Related Experiment Video
Updated: Dec 14, 2025

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Guide-wire replacement of a mini-midline catheter with a central venous catheter: A retrospective study on 63 cases
Lucio Brugioni1, Elisabetta Bertellini2, Mirco Ravazzini2
1Medicina d'Emergenza-Urgenza, Università degli Studi di Modena e Reggio Emilia, Modena, Italy.
Background:
Achieving a reliable venous access in a particular subset of patients and/or in emergency settings can be challenging and time-consuming. Furthermore, many hospitalized patients do not meet the criteria for central venous catheter positioning, unless an upgrade of the treatment is further needed. The mini-midline catheter has already showed to be reliable and safe as a stand-alone device, since it is easily and rapidly inserted and can indwell up to 1 month.
Methods:
In this further case series, we retrospectively evaluated data from 63 patients where a previously inserted mini-midline catheter was upgraded to a central venous catheter (the devices inserted in the arm replaced by peripherally inserted central catheter and others inserted "off-label" in the internal jugular replaced by single lumen centrally inserted central catheter), being used as introducer for the Seldinger guidewire.
Results:
The guidewire replacement was been made even early (after 1 day) or late (more than 10 days), usually following a need for an upgrade in treatment. No early or late complications were reported.
Conclusion:
According to the preliminary data we collected, this converting procedure seems to be feasible and risk-free, since neither infectious nor thrombotic complications were reported.
Related Concept Videos
Aneurysm IV: Nursing Management
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management