Cost-function testing methodology for image-based registration of endoscopy to CT images in the head and neck
Runjie B Shi1, Souzan Mirza2, Diego Martinez1
1Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto M5G 1X6, Canada.
None:
One of the largest geometric uncertainties in designing radiotherapy treatment plans for squamous cell cancers of the head and neck is contouring the gross tumor volume. We have previously described a method of projecting mucosal disease contours, visible on endoscopy, to volumetrically reconstructed planning computed tomography (CT) datasets, using electromagnetic (EM) tracking of a flexible endoscope, enabling rigid registration between endoscopic and CT images.However, to achieve better accuracy for radiotherapy planning, we propose refining this initial registration with image-based registration methods. In this paper, several types of cost functions are evaluated based on accuracy and robustness. Three phantoms and eight clinical cases are used to test each cost function, with initial registration of endoscopy to CT provided by the pose of the flexible endoscope recovered from EM tracking. Cost function classes include: cross correlation, mutual information and gradient methods. For each test case, a ground truth virtual camera pose was first defined by manual registration of anatomical features visible in both real and virtual endoscope images. A new set of evenly spaced fiducial points and a sample contour were created and projected onto the CT image to be used in assessing image registration quality. A new set of 5000 displaced poses was generated by random sampling displacements along each translational and rotational dimension. At each pose, fiducial and contour points in the real image were again projected on the CT image. The cost function, fiducial registration error and contouring error values were then calculated.While all cost functions performed well in select cases, only the normalized gradient field function consistently had registration errors less than 2 mm, which is the accuracy needed if this application of registering mucosal disease identified on optical image to CT images is to be used in the clinical practice of radiation treatment planning.(Registration: ClinicalTrials.gov NCT02704169).
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System V: CT