Related Experiment Video
Updated: Dec 14, 2025

Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model
Published on: September 14, 2009
Titanium-Nitride-Oxide-Coated Versus Everolimus-Eluting Stents in Acute Coronary Syndrome: The Randomized TIDES-ACS
Pim A L Tonino1, Nico H J Pijls2, Carlos Collet3
1Department of Cardiology, Catharina Hospital, Eindhoven, the Netherlands.
Objectives:
This study sought to compare next-generation cobalt-chromium-based titanium-nitride-oxide (TiNO)-coated stents with a platinum-chromium-based biodegradable polymer everolimus-eluting stent (EES) in patients with acute coronary syndrome (ACS).
Background:
Previous generation TiNO-coated stents showed acceptable performance in patients with ACS.
Methods:
In a multicenter, randomized trial, we randomly assigned 1,491 ACS patients (2:1) to receive either a TiNO-coated stent (n = 989) or EES (n = 502). The primary endpoint was the rate of a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 12-month follow-up. The co-primary endpoint was a composite of cardiac death, MI, or major bleeding at 18 months.
Results:
A primary endpoint event occurred in 6.3% of patients in the TiNO-coated stent group versus in 7.0% in the EES group (hazard ratio: 0.93; 95% confidence interval: 0.71 to 1.22; p = 0.66 for superiority; p < 0.001 for noninferiority). A co-primary endpoint event occurred in 3.7% of the patients in the TiNO group and in 7.8% in the EES group (hazard ratio: 0.64; 95% confidence interval: 0.51 to 0.80; p = 0.001). TiNO-coated stents were associated with lower rates of cardiac death (0.6% vs. 2.6%; p = 0.002) and MI (2.2% vs. 5.0%; p = 0.007) at 18 months of follow-up. Rates of target lesion revascularization were not significantly different at 18 months (5.8% vs. 4.4%; p = 0.27).
Conclusions:
In patients with ACS, cobalt-chromium-based TiNO-coated stents were noninferior to platinum-chromium-based biodegradable polymer EES for major cardiac events at 12 months, and were superior for the co-primary endpoint of cardiac death, MI, and bleeding at 18 months. (Comparison of Titanium-Nitride-Oxide-Coated Bio-Active-Stent (Optimax™) to the Drug (Everolimus) -Eluting Stent (Synergy™) in Acute Coronary Syndrome [TIDES-ACS]; NCT02049229).
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
04:30A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Related Concept Videos
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Acute Coronary Syndrome V: Nursing Management
Acute Coronary Syndrome IV: Interprofessional Care