Related Experiment Video
Updated: Dec 13, 2025

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Identification of metabolic markers in patients with type 2 Diabetes by Ultrafast gas chromatography coupled to
Karen Beatriz Méndez-Rodríguez1, Nicté Figueroa-Vega2, César Arturo Ilizaliturri-Hernandez1
1Coordinación para la Innovación y Aplicación de la Ciencia y la Tecnología (CIACyT), Universidad Autónoma de San Luis Potosí, San Luis Potosí, S.L.P., Mexico.
Abstract:
Metabolomics is a potential tool for the discovery of new biomarkers in the early diagnosis of diseases. An ultra-fast gas chromatography system equipped to an electronic nose detector (FGC eNose) was used to identify the metabolomic profile of Volatile Organic Compounds (VOCs) in type 2 diabetes (T2D) urine from Mexican population. A cross-sectional, comparative, and clinical study with translational approach was performed. We recruited twenty T2D patients and twenty-one healthy subjects. Urine samples were taken and analyzed by FGC eNose. Eighty-eight compounds were identified through Kovats's indexes. A natural variation of 30% between the metabolites, expressed by study groups, was observed in Principal Component 1 and 2 with a significant difference (p < 0.001). The model, performed through a Canonical Analysis of Principal coordinated (CAP), allowed a correct classification of 84.6% between healthy and T2D patients, with a 15.4% error. The metabolites 2-propenal, 2-propanol, butane- 2,3-dione and 2-methylpropanal, were increased in patients with T2D, and they were strongly correlated with discrimination between clinically healthy people and T2D patients. This study identified metabolites in urine through FGC eNose that can be used as biomarkers in the identification of T2D patients. However, more studies are needed for its implementation in clinical practice.
More Related Videos
12:24Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...