Related Experiment Video
Updated: Dec 13, 2025

Electrochemically and Bioelectrochemically Induced Ammonium Recovery
Published on: January 22, 2015
A bioelectrochemical-system-based trickling filter reactor for wastewater treatment
Qiaochu Liang1, Takahiro Yamashita2, Kazuyoshi Koike1
1Graduate School of Natural Science & Technology, Kanazawa University, Kakuma-machi, Kanazawa, Ishikawa 920-1192, Japan.
Abstract:
A bioelectrochemical system (BES)-based trickling filter (TF) reactor was utilized for wastewater treatment. At a COD load of 1.0 g-COD/L/day, effluent chemical oxygen demand (COD) and total nitrogen (TN) were 115 and 108 mg/L, respectively, which were allowed for discharge. Superior performance was achieved at 0.5 g-COD/L/day with a circulation rate of 8 L/h, and both COD and TN removal were >98%. Coulombic efficiency was 11% at 1.0 g-COD/L/day and at most 16% at 0.5 g-COD/L/day. COD removal decreased when the BES was removed, demonstrating that BES improved COD removal capability. In anodic biofilms, exoelectrogenic, facultative, nitrifying, and sulfate-reducing bacteria could coexist. Geobacter for current generation grew inside the biofilm, and bacteria in the middle and outer layers consumed oxygen and degraded organic matter and nitrogen. This BES-based TF reactor may be used for efficient and cost-effective COD and TN removal at high loads without excess sludge removal.