Related Experiment Video
Updated: Dec 13, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
The Rtx-Dioxin2 and Rxi-17SilMS as Alternative Gas Chromatographic Confirmation Columns for Dioxin Analysis
1Department of Chemistry, The Pennsylvania State University, 104 Chemistry Building, University Park, Pennsylvania 16802, United States.
Abstract:
Polychlorinated dibenzo-p-dioxins and furans are environmentally persistent and highly toxic compounds. 136 chlorinated dioxins and furan congeners contain at least four chlorine atoms and pose a complex separation challenge in environmental and biological matrixes. The complexity arises from the dioxin and furan molecules with substitutions at positions 2, 3, 7, and 8, which are toxicologically relevant but are not easily separated from the other non-/less toxic congeners. Many regulatory methods require the use of two columns with different polarities or selectivity for dioxin analysis. The most common confirmation column pair is a (5% phenyl)-methylpolysiloxane and a (biscyanopropyl-/ cyanopropylphenyl)-methylpolysiloxane. These phases are required in USEPA-1613 for 2,3,7,8-tetrachlorodibenzo-p-dioxin and 2,3,7,8-tetrachlorodibenzofuran specificity. However, other column phases, such as the Rxi-17SilMS and the Rtx-Dioxin2, offer alternatives to the traditional column pairing and provide a similar or better separation of 2,3,7,8-substituted congeners. This study compares four columns for dioxin analysis: the Rtx-Dioxin2, Rxi-17SilMS, Rxi-5SilMS, and Rtx-2330. All columns used in this study are capable of meeting the requirements for dioxin analysis required by USEPA-1613. However, the Rtx-Dioxin2 demonstrated improved selectivity for a wider range of dioxin compounds than the Rxi-5SilMS. The Rtx-Dioxin2 is capable of resolving 2,3,7,8-tetrachlorodibenzo-p-dioxin and 2,3,7,8-tetrachlorodibenzofuran from common interferants better than the Rxi-5SilMS and can be used as a confirmation column with either the Rtx-2330 or Rxi-17SilMS.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II

