Purpose:
The primary objective of this study was to determine the degree of patient satisfaction at a minimum of 5 years of follow-up after endoscopic calcaneoplasty. The secondary objectives were to assess functional outcome measures, pain scores, analysis of bone removal, reformation of exostosis at follow-up and correlation of the size of the exostosis and recurrent or persisting complaints.
Methods:
This study evaluated patients who underwent endoscopic calcaneoplasty, between January 1st 2000 and December 31st 2010, for the diagnosis of retrocalcaneal bursitis. The evaluation consisted of PROMs (patient-reported outcome measures), a questionnaire and a visit to the outpatient clinic for physical examination and a standard lateral weight-bearing radiograph of the ankle. Patient satisfaction, functional outcomes and pain scores were measured by use of a numeric rating scale (NRS). Size of the posterosuperior calcaneal exostosis was measured on a standard lateral weight-bearing radiograph using parallel pitch lines (PPL) and the Fowler-Philip angle (PFA).
Results:
The response rate was 28 out of 55 (51%) and the median time to follow-up was 101(IQR 88.5-131.8) months. The median satisfaction score for treatment results was 8.5 out of 10 (IQR 6-10). FAOS symptoms 84.5 (IQR 58.0-96.4), FAOS pain 90.3 (IQR 45.1-100.0), FAOS ADL 94.9 (IQR 58.1-100.0), FAOS sport 90.0 (IQR 36.3-100.0) and FAOS QOL 71.9 (IQR 37.5-93.8) and median AOFAS was 100 (IQR 89-100). The median PLL difference between before operation and 2 weeks after the operation was - 4 mm (IQR-6 and -1) and the median PLL difference between 2 weeks after the operation and at follow-up was 1 mm (0-2). The median PFA was 65 (63-69) at baseline, 66.5 (60.8-70.3) 2 weeks after the operation and 64 (60.8-65.3) at follow-up.
Conclusion:
Despite the limited response rate, this study shows high patient satisfaction and good long-term functional outcome in patients affected by retrocalcaneal bursitis who underwent endoscopic calcaneoplasty.
Level Of Evidence:
Level IV.