A novel index combining diastolic and systolic tissue Doppler parameters for predicting cardiac resynchronization
Selma Ari1, Hasan Ari1, Ahmet Tütüncü1
1Department of Cardiology, Bursa Postgraduate Hospital, Bursa, Turkey.
Objective:
Identification of patients who are nonresponders to cardiac resynchronization therapy (CRT) with the use of simple and objective parameters may be helpful in tailoring treatment. The aim of this study is to investigate whether E/(Ea × Sa) could be a predictor of CRT nonresponders (E = early diastolic transmitral velocity, Ea = early diastolic mitral annular velocity, Sa = systolic mitral annular velocity).
Methods:
In total, 53 heart failure patients were evaluated for this study, and 33 patients were included according to the study criteria. Before and 6 months after CRT-D(CRT with a defibrillator) implantation, E, Ea, and Sa were determined at the medial and lateral mitral annular sites, and the average values were obtained. E/(Ea × Sa) was calculated (medial, lateral, average). The patients were followed for 6 months to monitor their CRT response. A responder was defined as a patient with a reduction in end-systolic volume of ≥15% and an increase in 6-minute walking distance of 50 m.
Results:
At a 6-month follow-up, 24 (72.7%) of the 33 patients responded to CRT. At the 6-month follow-up, in the responder group, the E/Ea ratio, lateral mitral, and average E/(Ea × Sa) indices were significantly reduced (P < .01 for all). The baseline lateral mitral, medial mitral, and average E/(Ea × Sa) indices were significantly lower in the responder group than in the nonresponder group (P ≤ .01 for all). The receiver operating characteristic analysis showed that all the E/(Ea × Sa) indices predict the CRT nonresponder patients. The AUC values were 0.89 (lateral E/(Ea × Sa)), 0.85 (average E/(Ea × Sa)), and 0.77 (medial E/(Ea × Sa)) (P ≤ .01 for all).
Conclusion:
We found that the E/(Ea × Sa) index is a novel predictor of CRT nonresponder patients.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiomyopathy II: Dilated Cardiomyopathy