Related Experiment Video
Updated: Dec 13, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Surface-enhanced Raman spectroscopy (SERS) for detection of VX and HD in the gas phase using a hand-held Raman
Vered Heleg-Shabtai1, Hagai Sharabi, Amalia Zaltsman
1Department of Physical Chemistry, Israel Institute for Biological Research, P.O. Box 19, Ness-Ziona 74100, Israel. veredhs@iibr.gov.il alexanderp@iibr.gov.il.
Abstract:
A sensitive surface-enhanced Raman spectroscopy (SERS) substrate was developed to enable hand-held Raman spectrometers to detect gas-phase VX and HD. The substrate comprised Au nanoparticles modified onto quartz fibres. Limits of detection (LOD) of 0.008 μg L-1 and 0.054 μg L-1 were achieved for VX and HD, respectively. Gas-phase experiments were performed using a homemade gas-phase flow system inside a climatic chamber at 25 °C and 50% relative humidity. Preliminary experiments were conducted using VX and HD in solution with Au and Ag nanoparticle colloidal suspensions. We developed and optimized several SERS methods for detection of VX and HD in solution. Gold nanoparticles were optimal for detection of VX and HD and were modified onto quartz fibres for gas-phase detection. The LODs for HD and VX detection in solution were 1.8 × 10-3 μg mL-1 (1.1 × 10-8 M) and 2.5 × 10-3 μg mL-1 (9.3 × 10-9 M), respectively. This study demonstrates that integration of SERS substrates with hand-held Raman spectrometers expands the applicability of Raman technology to homeland security, as reflected by increased sensitivity and gas-phase detection capabilities.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...