Objective:
The electrochemical analysis of ephedrine which is a sympathometric drug has been studied using poly(Nile blue A) modified glassy carbon electrodes, cyclic voltammetry, differential pulse voltammetry and square wave voltammetry.
Methods:
The modified electrodes were prepared by potential cycling electropolymerization of Nile blue A in 0.1 M phosphate buffer solution at pH 6.0. The redox behavior of ephedrine was investigated in different buffer solutions at pH values between 5.5 and 9.0.
Results:
Scan rate studies showed that the electron transfer reaction of ephedrine was diffusion controlled. A linear response was obtained between the peak current and the ephedrine concentration in the range of 0.6 to 100 μM with a limit of detection of 2.91×10-3 μM for differential pulse voltammetry in Britton-Robinson buffer solution at pH 9.0. The linearity range of ephedrine in human urine was between 1.0 and 100 μM with a detection limit of 8.16 nM.
Conclusion:
The recovery studies in both pharmaceutical dosage forms and urine showed that the proposed method ensured good selectivity, precision and accuracy without any interference from inactive excipients.
More Related Videos
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
11:44Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...