Background:
Extremity exposures may raise the risk of cancer induction among radiographers involved in the preparation and administration of technetium-99m labelled radiopharmaceuticals.
Objective:
To estimate finger doses on radiographers at a South African tertiary hospital.
Methods:
Adhesive tape was used to securely fix a calibrated thermoluminescent dosimeter (TLD) on fingertips and bases of ring and index fingers of both hands of five radiographers who prepared and administered technetium-99m labelled radiopharmaceuticals. Rubber gloves were worn to avoid TLD contamination. TLDs doses were read with a Harsaw TLD Reader (Model 3500) after a week.
Results:
Five radiographers prepared and administered technitium-99m labelled radiopharmaceuticals (activity range; 78.20 GBq - 132.78 GBq during a one-week measurement period). A radiographer handling 132.78 GBq received 4.74±0.52 mSv on both hands; 5.52, 4.55, 5.11 and 4.60 mSv on the fingertip of the index finger of the dominant hand (FIDH), fingertip of the ring finger of the dominant hand (FRDH), fingertip of the index finger of the non-dominant hand (FINDH) and fingertip of the ring finger of the non-dominant hand (FRNDH), respectively. The respective doses received on the finger bases were 4.50 mSv, 4.60, 4.21 and 3.48 mSv. The radiographer handling 78.20 GBq received 0.85±0.18 mSv on both hands, 1.04, 1.17, 0.77 and 1 mSv for the FIDH, FRDH, FINDH and FRNDH, respectively, while respective doses for the bases were 0.8, 0.9, 0.6 and 0.8 mSv.
Conclusion:
The extremity exposures were below the annual limit (500 mSv). However, the use of syringe shields could still reduce the finger doses further.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:52In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy
Published on: December 9, 2015
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...