Related Experiment Video
Updated: Dec 13, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Range of Radiologist Performance in a Population-based Screening Cohort of 1 Million Digital Mammography Examinations
Mattie Salim1, Karin Dembrower1, Martin Eklund1
1From the Departments of Pathology and Oncology (M.S., F.S.), Physiology and Pharmacology (K.D., P.L.), and Medical Epidemiology and Biostatistics (M.E.), Karolinska Institute, Stockholm, Sweden; Department of Radiology (M.S.) and Breast Radiology (F.S.), Karolinska University Hospital, Dalagatan 90, 113 43 Stockholm, Sweden; and the Department of Radiology, Capio Sankt Görans Hospital, Stockholm, Sweden (K.D.).
Abstract:
Background There is great interest in developing artificial intelligence (AI)-based computer-aided detection (CAD) systems for use in screening mammography. Comparative performance benchmarks from true screening cohorts are needed. Purpose To determine the range of human first-reader performance measures within a population-based screening cohort of 1 million screening mammograms to gauge the performance of emerging AI CAD systems. Materials and Methods This retrospective study consisted of all screening mammograms in women aged 40-74 years in Stockholm County, Sweden, who underwent screening with full-field digital mammography between 2008 and 2015. There were 110 interpreting radiologists, of whom 24 were defined as high-volume readers (ie, those who interpreted more than 5000 annual screening mammograms). A true-positive finding was defined as the presence of a pathology-confirmed cancer within 12 months. Performance benchmarks included sensitivity and specificity, examined per quartile of radiologists' performance. First-reader sensitivity was determined for each tumor subgroup, overall and by quartile of high-volume reader sensitivity. Screening outcomes were examined based on the first reader's sensitivity quartile with 10 000 screening mammograms per quartile. Linear regression models were fitted to test for a linear trend across quartiles of performance. Results A total of 418 041 women (mean age, 54 years ± 10 [standard deviation]) were included, and 1 186 045 digital mammograms were evaluated, with 972 899 assessed by high-volume readers. Overall sensitivity was 73% (95% confidence interval [CI]: 69%, 77%), and overall specificity was 96% (95% CI: 95%, 97%). The mean values per quartile of high-volume reader performance ranged from 63% to 84% for sensitivity and from 95% to 98% for specificity. The sensitivity difference was very large for basal cancers, with the least sensitive and most sensitive high-volume readers detecting 53% and 89% of cancers, respectively (P < .001). Conclusion Benchmarks showed a wide range of performance differences between high-volume readers. Sensitivity varied by tumor characteristics. © RSNA, 2020 Online supplemental material is available for this article.
More Related Videos
09:00Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education
Published on: August 16, 2024
08:14MicroRNA Based Liquid Biopsy: The Experience of the Plasma miRNA Signature Classifier MSC for Lung Cancer Screening
Published on: October 26, 2017
Related Concept Videos
Radiological Investigation I: X-ray and CT
Receiver Operating Characteristic Plot
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...