Related Experiment Video
Updated: Dec 13, 2025

Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Multimodality imaging assessment of mitral annular disjunction in mitral valve prolapse
Valentina Mantegazza1, Valentina Volpato2, Paola Gripari2
1Department of Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy valentina.mantegazza@cardiologicomonzino.it.
Objective:
Mitral annular disjunction (MAD) is an abnormality linked to mitral valve prolapse (MVP), possibly associated with malignant ventricular arrhythmias. We assessed the agreement among different imaging techniques for MAD identification and measurement.
Methods:
131 patients with MVP and significant mitral regurgitation undergoing transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) were retrospectively enrolled. Transoesophageal echocardiography (TOE) was available in 106 patients. MAD was evaluated in standard long-axis views (four-chamber, two-chamber, three-chamber) by each technique.
Results:
Considering any-length MAD, MAD prevalence was 17.3%, 25.5%, 42.0% by TTE, TOE and CMR, respectively (p<0.05). The agreement on MAD identification was moderate between TTE and CMR (κ=0.54, 95% CI 0.49 to 0.59) and good between TOE and CMR (κ=0.79, 95% CI 0.74 to 0.84). Assuming CMR as reference and according to different cut-off values for MAD (≥2 mm, ≥4 mm, ≥6 mm), specificity (95% CI) of TTE and TOE was 99.6 (99.0 to 100.0)% and 98.7 (97.4 to 100.0)%; 99.3 (98.4 to 100.0)% and 97.6 (95.8 to 99.4)%; 97.8 (96.2 to 99.3)% and 93.2 (90.3 to 96.1)%, respectively; sensitivity (95% CI) was 43.1 (37.8 to 48.4)% and 74.5 (69.4 to 79.5)%; 54.0 (48.7 to 59.3)% and 88.9 (85.2 to 92.5)%; 88.0 (84.5 to 91.5)% and 100.0 (100.0 to 100.0)%, respectively. MAD length was 8.0 (7.0-10.0), 7.0 (5.0-8.0], 5.0 (4.0-7.0) mm, respectively by TTE, TOE and CMR. Agreement on MAD measurement was moderate between TTE and CMR (ρ=0.73) and strong between TOE and CMR (ρ=0.86).
Conclusions:
An integrated imaging approach could be necessary for a comprehensive assessment of patients with MVP and symptoms suggestive for arrhythmias. If echocardiography is fundamental for the anatomic and haemodynamic characterisation of the MV disease, CMR may better identify small length MAD as well as myocardial fibrosis.
Related Concept Videos
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Valve Prolapse II: Assessment and Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Valve Prolapse I: Introduction
Mitral Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests

