Yuyu Chen1,2, Haishan Xu1,2, Shenghua Ding3
1College of Food Science and Technology Hunan Agricultural University Changsha China.
Abstract:
Changes in volatile compounds of fermented minced pepper (FMP) during natural fermentation (NF) and inoculated fermentation (IF) process were analyzed by the headspace-gas chromatography-ion mobility spectrometry (HS-GC-IMS). A total of 53 volatile compounds were identified, including 12 esters, 17 aldehydes, 13 alcohols, four ketones, three furans, two acids, one pyrazine, and one ether. Generally, fermentation time played an important role in volatile compounds of FMP. It was found that most esters, aldehydes, and alcohols obviously decreased with the increase in fermentation time, including isoamyl hexanoate, methyl octanoate, gamma-butyrolactone, phenylacetaldehyde, methional, and E-2-hexenol. Only a few volatile compounds increased, especially for 2-methylbutanoic acid, 2-methylpropionic acid, linalool, ethanol, and ethyl acetate. However, no significant difference in volatile compounds was found between NF and IF samples at the same fermentation time. In addition, the fermentation process in all samples was well discriminated as three stages (0 days; 6 day; and 12, 18, and 24 days), and all volatile compounds were divided into two categories (increase and decrease) based on principal component analysis and heat map.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Volatilization
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...