Objective:
The design of the stimulation paradigm plays an important role in steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) studies. Among various stimulation designs, the dual-frequency paradigm in which two frequencies are used to encode one target is of importance and interest. However, because the number of possible frequency combinations is huge, the existing dual-frequency modulation paradigms failed to optimize the encoding towards the best combinations. Thus, this work aiming at designing a new dual-frequency and phase modulation paradigm with the best combinations stimuli.
Approach:
This study proposed a dual-frequency and phase modulation method, which can achieve a large number of targets by making different combinations of two frequencies and an initial phase. This study also designed a set of methods for quickly optimizing the stimulation codes for the dual-frequency and phase modulation method.
Main Results:
An online 40-class BCI experiment with 12 subjects obtained an accuracy of 96.06[Formula: see text]4.00% and an averaged information transfer rate (ITR) of 196.09[Formula: see text]15.25 bits min-1, which were much higher than the existing dual-frequency modulation paradigms. Moreover, an offline simulation with a public dataset showed that the optimization method was also effective for optimizing the single-frequency and phase modulation paradigm.
Significance:
These results demonstrate the high performance of the proposed dual-frequency and phase modulation method and the high efficiency of the optimization method for designing SSVEP stimulation paradigms. In addition, the coding efficiency of the optimized dual-frequency and phase modulation paradigm is higher than that of the single-frequency and phase modulation paradigm, and it is expected to further realize the BCI paradigm with a large amount of targets.
More Related Videos
06:34A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare
Published on: July 7, 2023
08:25Combined Invasive Subcortical and Non-invasive Surface Neurophysiological Recordings for the Assessment of Cognitive and Emotional Functions in Humans
Published on: May 19, 2016
Related Concept Videos
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Power Factor Correction
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...