Related Experiment Video
Updated: Dec 13, 2025

Surgical Bone Implantation Technique for Rat Tibia Models of Diabetes and Osteoporosis
Published on: July 5, 2024
Data on biomechanics and elemental maps of dental implant-bone complexes in rats
B Wang1, K Kim1, S Srirangapatanam2
1Department of Preventive and Restorative Dental Sciences, School of Dentistry, UCSF, San Francisco, CA 94143, USA.
Abstract:
Implant-bone biomechanics and mechanoadaptation of peri‑implant tissue in space (around and along the length of an implant) and time (3-, 11-, and 24-day following implantation) are important for functional osseointegration of dental implants. Spatiotemporal shifts in biomechanics of implant-bone complex in rat maxillae were correlated with maximum (tensile) and minimum (compressive) principal strain profiles in peri‑implant tissue using a hybrid model; biomechanics in situ paired with digital volume correlation. Spatiotemporal changes in elemental counts and their association with mineral density of the peri‑implant tissue were mapped using electron dispersive X-ray and X-ray fluorescence microprobe techniques. Data provided within are related to biomechanical testing of an implant-bone complex in situ. Data also highlight the power of correlating elemental colocalization with tension and compression regions of the peri‑implant tissues to explain spatiotemporal mechanoadaptation of implant-bone complexes. Further interpretation of data is provided in "Mechanoadaptive Strain and Functional Osseointegration of Dental Implants in Rats [1]."