Identification of the origin of infantile saturnism based on lead isotopic and elemental ratios

Benedicte Lelievre1, Chloe Bruneau2, Marion Legeay2

  • 1Laboratoire de pharmacologie-toxicologie, CHU Angers, France; Groupe d'Étude des Interactions Hôte-Pathogène (GEIHP) EA 3142, Université d'Angers-Université de Brest, Angers, France.

Insights

This case study highlights severe lead poisoning in a child with pica. Inductively coupled plasma-mass spectrometry (ICP-MS) identified the lead source, enabling prompt intervention and positive outcomes.

Area of Science:

  • Environmental Health
  • Pediatric Toxicology
  • Analytical Chemistry

Background:

  • Childhood lead poisoning is decreasing in France due to reduced lead use in paints and water systems.
  • Chronic lead toxicity is a known health concern, directly correlated with blood lead levels.

Observation:

  • A young female child presented with severe lead poisoning.
  • The child exhibited pica behavior, a potential indicator of lead exposure.

Findings:

  • Inductively coupled plasma-mass spectrometry (ICP-MS) was used to analyze blood and environmental samples.
  • Lead isotope ratios (e.g., 208Pb/206Pb, 206Pb/207Pb) and cadmium-to-lead ratios (Cd/Pb) successfully identified the contamination source.

Implications:

  • The identified lead source was eliminated, leading to a positive outcome for the child.
  • Elemental and isotopic ratio analysis via ICP-MS offers valuable clinical insights for rapid diagnosis and source identification in lead poisoning cases.
Abstract

Related Concept Videos

Radioactive Decay and Radiometric Dating02:48

Radioactive Decay and Radiometric Dating

Radioactivity is a spontaneous disintegration of an unstable nuclide and is a random process, as all the nuclei in the sample do not decay simultaneously. The number of disintegrations per unit time is called the activity (A), which is directly proportional to the number of nuclei in the sample. The decay constant (λ) is an average probability of decay per nucleus in unit time.
36.2K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.1K
Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
3.6K