Related Experiment Video
Updated: Dec 13, 2025

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Reverse Total Shoulder Arthroplasty with a Superior Augmented Glenoid Component for Favard Type-E1, E2, and E3
Lindsey Liuzza1, David H Mai1, Sean Grey2
1NYU Langone Orthopedic Hospital, New York, NY.
Reverse total shoulder arthroplasty (rTSA) with augmented baseplates effectively treats superior glenoid wear, showing significant improvements in pain and function. Further long-term studies are needed to confirm durability.
Area of Science:
- Orthopedic Surgery
- Biomedical Engineering
- Musculoskeletal Research
Background:
- Superior glenoid wear in reverse total shoulder arthroplasty (rTSA) can lead to complications like baseplate failure.
- Favard types E1, E2, and E3 glenoid deformities present unique challenges in shoulder arthroplasty.
- Augmented glenoid baseplates aim to address complex glenoid anatomy and improve outcomes.
Purpose of the Study:
- To evaluate the clinical and radiographic outcomes of rTSA using superior or superior/posterior augmented baseplates for Favard type E1, E2, and E3 glenoid deformities.
- To quantify improvements in shoulder range of motion and patient-reported outcome scores.
- To assess the complication rates associated with this surgical technique.
Main Methods:
- Retrospective review of 68 patients undergoing primary rTSA with augmented baseplates for specific glenoid deformities.
- Follow-up averaged 40 months, assessing range of motion and outcome scores (SST, UCLA, ASES, Constant, SPADI).
- Preoperative and postoperative radiographs were analyzed; statistical analysis used a 2-tailed Student t test.
Main Results:
- Significant improvements in pain and function were observed, with 94% of patients reporting feeling
- better
- or
- much better
- . * At least 88% of patients exceeded the minimum clinically important difference (MCID) and 75% exceeded the substantial clinical benefit (SCB) thresholds for key metrics.
- Five complications (7.4%) were reported, including fractures and aseptic loosening.
Conclusions:
- rTSA with superior or superior/posterior augmented baseplates is a successful short-term treatment for shoulder arthropathy with superior glenoid wear patterns (Favard types E1-E3).
- The technique demonstrates promising clinical and functional improvements.
- Longer-term follow-up is required to confirm the durability of these outcomes.