Spectrally Dependent CLARREO Infrared Spectrometer Calibration Requirement for Climate Change Detection
Xu Liu1, Wan Wu2, Bruce A Wielicki1
1NASA Langley Research Center, Hampton, Virginia.
Abstract:
Detecting climate trends of atmospheric temperature, moisture, cloud, and surface temperature requires accurately calibrated satellite instruments such as the Climate Absolute Radiance and Reflectivity Observatory (CLARREO). Wielicki et al. have studied the CLARREO measurement requirements for achieving climate change accuracy goals in orbit. Our study further quantifies the spectrally dependent IR instrument calibration requirement for detecting trends of atmospheric temperature and moisture profiles. The temperature, water vapor, and surface skin temperature variability and the associated correlation time are derived using Modern Era Retrospective-Analysis for Research and Applications (MERRA) and European Center for Medium-Range Weather Forecasts (ECMWF) reanalysis data. The results are further validated using climate model simulation results. With the derived natural variability as the reference, the calibration requirement is established by carrying out a simulation study for CLARREO observations of various atmospheric states under all-sky. We derive a 0.04 K (k=2, or 95% confidence) radiometric calibration requirement baseline using a spectral fingerprinting method. We also demonstrate that the requirement is spectrally dependent and some spectral regions can be relaxed due to the hyperspectral nature of the CLARREO instrument. We further discuss relaxing the requirement to 0.06 K (k=2) based on the uncertainties associated with the temperature and water vapor natural variability and relatively small delay in time-to-detect for trends relative to the baseline case. The methodology used in this study can be extended to other parameters (such as clouds and CO2) and other instrument configurations.
Related Concept Videos
IR Spectrometers
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Applications of IR Spectroscopy: Overview