Related Experiment Video
Updated: Dec 13, 2025

Ye's Swing Technique for Small-incision Lenticule Extraction Surgery
Published on: June 27, 2025
Stab incision mitomycin C-assisted rapid trabeculectomy: A 'SMART' trabeculectomy alternative
Chryssa Terzidou1, Alexandra Trivli1, Georgios Dalianis1
1Department of Ophthalmology, Konstantopouleio-Patission General Hospital, Athens 14233, Greece.
The novel stab incision mitomycin C (MMC)-assisted rapid trabeculectomy (SMART) offers a faster, less invasive glaucoma surgery. This technique significantly reduces intraocular pressure (IOP) and medication dependence with minimal complications.
Area of Science:
- Ophthalmology
- Surgical Innovation
- Glaucoma Management
Background:
- Glaucoma surgery, particularly trabeculectomy, aims to reduce intraocular pressure (IOP).
- Traditional trabeculectomy involves significant surgical time and tissue manipulation.
- There is a need for modified techniques that are faster and less invasive.
Purpose of the Study:
- To introduce and evaluate a new modified trabeculectomy technique: stab incision mitomycin C (MMC)-assisted rapid trabeculectomy (SMART).
- To assess the safety, efficacy, and surgical characteristics of the SMART technique compared to classic trabeculectomy.
Main Methods:
- The SMART technique involves subconjunctival MMC injection, a small conjunctival opening, a stab incision into the anterior chamber, and double punch excision.
- A total of 41 eyes with glaucoma underwent the SMART procedure.
- Surgical time, tissue manipulation, intraocular pressure (IOP), and medication usage were recorded.
Main Results:
- The mean preoperative IOP was 23.8 mmHg, reduced to 11 mmHg one year post-surgery (a reduction of 12.8 mmHg).
- Mean medication use decreased from 3.3 to 0.7 post-surgery.
- The mean follow-up was 27.6 months, with all eyes maintaining IOP <15 mmHg and experiencing few minor complications.
Conclusions:
- SMART trabeculectomy is a safe, quick, and effective alternative to classic trabeculectomy.
- The technique requires less surgical time and tissue manipulation.
- Wound modulation with MMC in the SMART technique leads to significant IOP reduction and sustained control.