Related Experiment Video
Updated: Dec 13, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
KODA score: an updated and validated bowel preparation scale for patients undergoing small bowel capsule endoscopy
Mohammad Alageeli1, Brian Yan1, Suliman Alshankiti2
1Division of Gastroenterology, Western University, London, Ontario, Canada.
Abstract:
Background and study aims A reliable outcome measure is needed for bowel preparation quality during capsule endoscopy. Currently, no scales are adequately validated. Our objective was to update an existing small bowel preparation score, create a standardized training module, then determine its inter-rater and intra-rater reliability. Patients and methods Modification to produce standardized scoring of an existing small bowel preparation score was performed followed by development of a training module and validation to create the new Korea-Canada (KODA) score. Twenty readers from a range of backgrounds, including capsule endoscopists, gastroenterology fellows, residents, medical students, and nurses rated bowel cleanliness in 25 capsule videos consisting of 1,233 images, in duplicate 4 weeks apart, after completing the training module. Sequential images selected in 5-minute intervals during small bowel transit were rated on a scale between 0-3 based on the amount of visualized mucosa and the degree of obstruction. Reliability was assessed using estimates of intraclass correlation coefficients (ICCs). Results Intraclass correlation coefficients for inter-rater (ICC 0.81, 95 % CI 0.70-0.87) and intra-rater (ICC 0.92, 95 % CI 0.87-0.94) reliability were almost perfect among the 20 readers. Inter-rater reliability ranged between 0.72 (95 % CI 0.57-0.81) and 0.89 (95 % CI 0.79-0.93) for nurses and residents, respectively. Intra-rater reliability was greater than 0.90 for all groups except for nurses, which was still almost perfect (ICC 0.86, 95 % CI 0.79-0.90). Conclusions Almost perfect inter-rater and intra-rater reliability was observed for the KODA score. This simple score could be used for future clinical trials after completion of the training module.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures II: Colonoscopy
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures V: ERCP
Patient...