Related Experiment Video
Updated: Dec 13, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Blood loss in primary total hip arthroplasty with a short versus conventional cementless stem: a retrospective cohort
Mattia Loppini1,2, Antonello Della Rocca3, Davide Ferrentino3
1Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090, Pieve Emanuele, Milan, Italy. mattia.loppini@hunimed.eu.
Introduction:
To evaluate the impact of short cementless stem on several clinical and radiographic outcomes, with particular focus on blood loss, in comparison with conventional cementless stem in total hip arthroplasty (THA).
Materials And Methods:
Patients undergoing THA with GTS short stem or CLS conventional stem were included. Clinical data were retrospectively collected including preoperative and postoperative day 1 value for haemoglobin (HB); rate of postoperative blood transfusions; intraoperative bone infractions; stem alignment; 5-year follow-up Harris Hip Score (HHS) and rate of stem revision at 5 years of follow-up of the short and conventional cementless stem.
Results:
GTS and CLS stem group included 374 and 321 patients, respectively. The mean difference between the preoperative and postoperative day 1 HB value was 3.98 g/dL (SD 1.12) and 3.67 g/dL (SD 1.19) in the GTS and CLS group, respectively, which correspond to a crude effect (β) of 0.32 (95% CI 0.15; 0.49) and adjusted effect of 0.11 (95% CI - 0.08; 0.3). GTS group reported a significantly higher number of patients with excellent results in terms of HHS (p = 0.001). The rate of intraoperative bone infractions was 1.6% and 0.3% in the GTS and CLS group, respectively (p = 0.013). At radiographic assessment, the rate of varus position of the stem was 14% in the GTS group and 6% in the CLS group (p < 0.0001). The rate of stem revision at 5 years of follow-up was 0.8% and 0.4% in the GTS and CLS group, respectively (p = 0.63).
Conclusions:
GTS short stem was not associated with a clinically significant lower blood loss in the immediately postoperative period. Unadjusted exploratory analyses show that GTS stem provides the same results of CLS stem in terms of HHS and rate of stem revision at 5 years of follow-up.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
06:17Augmented Reality Navigation-Guided Core Decompression for Osteonecrosis of Femoral Head
Published on: April 12, 2022