A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Cross-validation of equations to predict whole-body sweat sodium concentration from regional measures during exercise
Lindsay B Baker1, Ryan P Nuccio1, Adam J Reimel1
1Gatorade Sports Science Institute, PepsiCo R&D Life Sciences, Barrington, IL, USA.
Abstract:
We have previously published equations to estimate whole-body (WB) sweat sodium concentration ([Na+ ]) from regional (REG) measures; however, a cross-validation is needed to corroborate the applicability of these prediction equations between studies. The purpose of this study was to determine the validity of published equations in predicting WB sweat [Na+ ] from REG measures when applied to a new data set. Forty-nine participants (34 men, 15 women; 75 ± 12 kg) cycled for 90 min while WB sweat [Na+ ] was measured using the washdown technique. REG sweat [Na+ ] was measured from seven regions using absorbent patches (3M Tegaderm + Pad). Published equations were applied to REG sweat [Na+ ] to determine predicted WB sweat [Na+ ]. Bland-Altman analysis of mean bias (raw and predicted minus measured) and 95% limits of agreement (LOA) were used to compare raw (uncorrected) REG sweat [Na+ ] and predicted WB sweat [Na+ ] to measured WB sweat [Na+ ]. Mean bias (±95% LOA) between raw REG sweat [Na+ ] and measured WB sweat [Na+ ] was 10(±20), 0(±19), 9(±20), 22(±25), 23(±24), 0(±15), -4(±18) mmol/L for the dorsal forearm, ventral forearm, upper arm, chest, upper back, thigh, and calf, respectively. The mean bias (±95% LOA) between predicted WB sweat [Na+ ] and measured WB sweat [Na+ ] was 3(±14), 4(±12), 0(±14), 2(±17), -2(±16), 5(±13), 4(±15) mmol/L for the dorsal forearm, ventral forearm, upper arm, chest, upper back, thigh, and calf, respectively. Prediction equations improve the accuracy of estimating WB sweat [Na+ ] from REG and are therefore recommended for use when determining individualized sweat electrolyte losses.
More Related Videos
07:32Use of Galvanic Skin Responses, Salivary Biomarkers, and Self-reports to Assess Undergraduate Student Performance During a Laboratory Exam Activity
Published on: February 10, 2016
08:33A Cross-Disciplinary and Multi-Modal Experimental Design for Studying Near-Real-Time Authentic Examination Experiences
Published on: September 4, 2019
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Multiple Regression
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Measurement of Blood Pressure