Francesco Cavallin1, Giulia Res2, Chiara Monfredini3
1, Solagna, Italy.
Abstract:
Tracheal suctioning in non-vigorous newborn delivered through meconium-stained amniotic fluid (MSAF) is supposed to delay initiation of positive pressure ventilation (PPV), but the magnitude of such delay is unknown. To compare the time of PPV initiation when performing immediate laryngoscopy with intubation and suctioning vs. performing immediate PPV without intubation in a manikin model. Randomized controlled crossover (AB/BA) trial comparing PPV initiation with or without endotracheal suctioning in a manikin model of non-vigorous neonates born through MSAF. Participants were 20 neonatologists and 20 pediatric residents trained in advanced airway management. Timing of PPV initiation was longer with vs. without endotracheal suctioning in both pediatric residents (mean difference 13 s, 95% confidence interval 8 to 18 s; p < 0.0001) and neonatologists (mean difference 12 s, 95% confidence interval 8 to 16 s; p < 0.0001). The difference in timing of PPV initiation was similar between pediatric residents and neonatologists (mean difference - 1 s, 95% confidence interval - 7 to 6 s; p = 0.85).Conclusions: Performing immediate laryngoscopy with intubation and suctioning was associated with longer-but not clinically relevant-time of initiation of PPV compared with immediate PPV without intubation in a manikin model. While suggesting negligible delay in starting PPV, further studies in a clinical setting are warranted.Registration: clinicaltrial.gov NCT04076189. What is Known: • Management of the non-vigorous newborn delivered through meconium-stained amniotic fluid remains still controversial. • Tracheal suctioning in non-vigorous newborn delivered through meconium-stained amniotic fluid is supposed to delay initiation of positive pressure ventilation, but the magnitude of such delay is unknown. What is New: • Performing immediate ventilation without intubation was associated with shorter-but not clinically relevant-time of initiation of ventilation compared to immediate laryngoscopy with intubation and suctioning in a manikin model. • Further studies in a clinical setting are warranted.
Related Concept Videos
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Mechanical Ventilation I: Indication and Settings