Related Experiment Video
Updated: Dec 13, 2025

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Simultaneous glomerular filtration rate determination using inulin, iohexol, and 99mTc-DTPA demonstrates the need for
Christine A White1, Ayub Akbari2, Celine Allen1
1Division of Nephrology, Department of Medicine, Queen's University, Kingston, Ontario, Canada.
Abstract:
Urinary inulin clearance is considered the gold standard of glomerular filtration rate (GFR) measurement but plasma clearance of less expensive and more accessible tracers is more commonly performed. Many plasma sampling protocols exist but little is known about their accuracy. Here, the study objectives were to compare plasma iohexol and 99mTc-DTPA GFR with varying sampling strategies to the GFR measured by urinary inulin and to identify protocols with the greatest accuracy according to clinical characteristics. GFR was measured simultaneously using urinary inulin, plasma iohexol, and plasma 99mTc DTPA clearance. Blood was sampled from 2 to 10 hours after injection. For each method, bias, precision, and accuracy (P30 and mean absolute error) were calculated for the entire cohort and for eGFR-EPI creatinine subgroups (<30, 30-59, and ≥60 ml/min/1.73m2) and the edema stage using urinary inulin clearance as the gold standard. The mean inulin GFR of the 77 participants was 33 ml/min/1.73m2. Delay of both the initial and the final samples in plasma iohexol protocols yielded the highest accuracy in the setting of low GFR (<30 ml/min/1.73m2). Early initial and final samples yielded the highest accuracy in the setting of high GFRs (≥60 ml/min/1.73m2). No sampling strategy was accurate in edematous patients. Thus, our study demonstrates that customization of GFR protocols according to the anticipated level of GFR are required to optimize protocol accuracy.
Related Concept Videos
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Imaging Studies III: Computed Tomography
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

