Related Experiment Video
Updated: Dec 13, 2025

Transient Optical Clearing Using Absorbing Molecules for Ex Vivo and In Vivo Imaging
Published on: July 11, 2025
Cooperative Low-Rank Models for Removing Stripe Noise From OCTA Images
Abstract:
Optical coherence tomography angiography (OCTA) is an emerging non-invasive imaging technique for imaging the microvasculature of the eye based on phase variance or amplitude decorrelation derived from repeated OCT images of the same tissue area. Stripe noise occurs during the OCTA acquisition process due to the involuntary movement of the eye. To remove the stripe noise (or 'destriping') effectively, we propose two novel image decomposition models to simultaneously destripe all the OCTA images of the same eye cooperatively: cooperative uniformity destriping (CUD) model and cooperative similarity destriping (CSD) model. Both the models consider stripe noise by low-rank constraint but in different ways: the CUD model assumes that stripe noise is identical across all the layers while the CSD model assumes that the stripe noise at different layers are different and have to be considered in the model. Compared to the CUD model, CSD is a more general solution for real OCTA images. An efficient solution (CSD+) is developed for model CSD to reduce the computational complexity. The models were extensively evaluated against state-of-the-art methods on both synthesized and real OCTA datasets. The experiments demonstrated not only the effectiveness of the CSD and CSD+ models in terms of peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) and CSD+ is twice faster than CSD, but also their beneficiary effect on the vessel segmentation of OCTA images. We expect our models will become a powerful tool for clinical applications.
Related Concept Videos
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Trimmed Mean
Although certain measures of central tendency are not sensitive to outliers, there are alternative versions of the mean that get around the...
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an...

