Real-Time Monitoring Method for Layered Compaction Quality of Loess Subgrade Based on Hydraulic Compactor
Tianyu Xu1, Zhijun Zhou1, Ruipeng Yan1
1School of Highway, Chang'an University, Xi'an 710064, China.
Abstract:
Hydraulic compactor is an efficient reinforcement machine for loess subgrade. However, it is difficult to control the layered compaction quality of the subgrade. This research presents a real-time layered compactness monitoring method for hydraulic compactor reinforcement of subgrade in loess areas. The hydraulic force coefficient is first introduced, and the dynamic response model of the hydraulic rammer and soil is established. The relationship between the acceleration of the hydraulic rammer and the compactness of subgrade is then obtained based on the collision theory in elastic half space. A full-scale test using a hydraulic compactor to reinforce loess subgrade was also carried out. Results show that the hydraulic compactor obtains the effective influence depth for the reinforcement of loess subgrade. Within the effective reinforcement depth, the relationship between the peak acceleration of the rammer and the layered compactness of subgrade can be well fitted by a quadratic function model. The layered compactness of the subgrade and the working state of the hydraulic compactor can then be remotely monitored at a mobile terminal in real time. Furthermore, the monitoring technology was applied to Huangling-Yan'an Expressway in China, significantly improving the accuracy and efficiency of real-time monitoring of the layered compactness of subgrade in the loess area.
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Non-destructive Tests for Concrete Strength
Design Example: Maintaining Level of an Embankment
Slump Test
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...