[18F]FDG uptake of the normal spinal cord in PET/MR imaging: comparison with PET/CT imaging
Marco Aiello1, Vincenzo Alfano2, Elena Salvatore3
1IRCCS SDN, Naples, Italy.
Background:
The lack of visualization of the spinal cord hinders the evaluation of [18F]Fluoro-deoxy-glucose (FDG) uptake of the spinal cord in PET/CT. By exploiting the capability of MRI to precisely outline the spinal cord, we performed a retrospective study aimed to define normal pattern of spinal cord [18F]FDG uptake in PET/MRI.
Methods:
Forty-one patients with lymphoma without clinical or MRI signs of spinal cord or bone marrow involvement underwent simultaneous PET and MRI acquisition using Siemens Biograph mMR after injection of 3.5 MBq/kg body weight of [18F]FDG for staging purposes. Using a custom-made software, we placed ROIs of 3 and 9 mm in diameter in the spinal cord, lumbar CSF, and vertebral marrow that were identified on MRI at 5 levels (C2, C5, T6, T12, and L3). The SUVmax, SUVmean, and the SUVmax and SUVmean normalized (NSUVmax and NSUVmean) to the liver were measured. For comparison, the same ROIs were placed in PET-CT images obtained immediately before the PET-MRI acquisition following the same tracer injection.
Results:
On PET/MRI using the 3 mm ROI, the following average (all level excluding L3) spinal cord median (1st and 3rd quartile) values were measured: SUVmean, 1.68 (1.39 and 1.83); SUVmax, 1.92 (1.60 and 2.14); NSUVmean, 1.18 (0.93 and 1.36); and NSUVmax, 1.27 (1.01 and 1.33). Using the 9 mm ROI, the corresponding values were SUVmean, 1.41 (1.25-1.55); SUVmax, 2.41 (2.08 and 2.61); NSUVmean, 0.93 (0.79 and 1.04); and NSUVmax, 1.28 (1.02 and 1.39). Using the 3 mm ROI, the highest values of PET-MRI SUVmax, SUVmean, NSUVmax, and NSUVmean were consistently observed at C5 and the lowest at T6. Using a 9 mm ROI, the highest values were consistently observed at C5 and the lowest at T12 or T6. The spinal cord [18F]FDG-uptake values correlated with the bone marrow uptake at the same level, especially in case of NSUVmax. Comparison with PET-CT data revealed that the average SUVmax and SUVmean of the spinal cord were similar in PET-MRI and PET-CT. However, the average NSUVmax and NSUVmean of the spinal cord were higher (range 21-47%) in PET-MRI than in PET-CT.
Conclusions:
Using a whole-body protocol, we defined the maximum and mean [18F]FDG uptake of the normal spinal cord in PET/MRI. While the observed values show the expected longitudinal distribution, they appear to be higher than those measured in PET/CT. Normalization of the SUVmax and SUVmean of the spinal cord to the liver radiotracer uptake could help in multi-institutional comparisons and studies.
Insights
This study defines normal spinal cord [18F]Fluoro-deoxy-glucose (FDG) uptake patterns using PET/MRI. Findings show higher normalized uptake values in PET/MRI compared to PET/CT, suggesting liver normalization for multi-institutional studies.
Area of Science:
- Nuclear Medicine
- Radiology
- Neuroimaging
Background:
- Spinal cord visualization is limited in PET/CT, hindering [18F]Fluoro-deoxy-glucose (FDG) uptake evaluation.
- MRI offers precise spinal cord outlining, enabling detailed uptake analysis.
- This study aimed to establish normal spinal cord [18F]FDG uptake patterns using PET/MRI.
Purpose of the Study:
- To define the normal pattern of spinal cord [18F]FDG uptake in PET/MRI.
- To compare [18F]FDG uptake values between PET/MRI and PET/CT.
- To assess the utility of liver normalization for multi-institutional comparisons.
Main Methods:
- Retrospective analysis of 41 lymphoma patients undergoing simultaneous PET/MRI.
- Regions of interest (ROIs) placed in the spinal cord, CSF, and bone marrow at 5 levels.
- Measurement of SUVmax, SUVmean, and normalized values (NSUVmax, NSUVmean) compared to liver uptake; comparison with pre-existing PET-CT data.
Main Results:
- Defined average spinal cord [18F]FDG uptake values (SUVmean, SUVmax, NSUVmean, NSUVmax) using 3mm and 9mm ROIs.
- Observed highest uptake at C5 and lowest at T6 or T12.
- PET/MRI showed higher average NSUVmax and NSUVmean (21-47%) compared to PET/CT, while SUVmax and SUVmean were similar.
Conclusions:
- Established normal [18F]FDG uptake values for the spinal cord in PET/MRI.
- Spinal cord [18F]FDG uptake in PET/MRI appears higher than in PET/CT.
- Liver normalization of SUV values is recommended for multi-institutional studies.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)