Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Automated pulse wave velocity assessment using a professional oscillometric office blood pressure monitor
Anastasios Kollias1, Konstantinos G Kyriakoulis1, Areti Gravvani1
1Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
Abstract:
Carotid-femoral pulse wave velocity (cfPWV) is the gold standard method for assessing arterial stiffness. This study evaluated automated brachial-ankle PWV (baPWV) taken by a professional oscillometric blood pressure monitor (Microlife WatchBP Office Vascular) versus reference cfPWV (Complior device). Subjects recruited from a hypertension outpatient clinic had duplicate baPWV and cfPWV measurements (randomized crossover design) and carotid ultrasonography. Of 102 subjects recruited, 101 had valid baPWV measurements. Four subjects were excluded and 97 were analyzed (age 58.3 ± 11.4 years, men 70%, hypertensives 76%, diabetics 17%, cardiovascular disease 10%, smokers 23%). The mean difference between baPWV (13.1 ± 1.8 m/s) and cfPWV (9.1 ± 1.8 m/s) was 4.0 ± 1.4 m/s (P < .01) with close association between them (r = 0.70, P < .01). baPWV and cfPWV were correlated with age (r 0.54/0.49 respectively), systolic blood pressure (0.45/0.50), carotid intima-media thickness (0.31/0.44), and carotid distensibility coefficient (-0.47/-0.34) (all P < .05; no difference between the two methods, z test). There was reasonable agreement (77%) between the two methods in identifying subjects at the top quartile of their distributions (kappa 0.39, P < .01). The areas under the receiver operating characteristic curves for the identification of carotid plaques were comparable for cfPWV and baPWV (0.79 and 0.74 respectively, P = NS). Automated baPWV measurement by a professional oscillometric blood pressure monitor is feasible and observer-independent. baPWV values differ from those by cfPWV, yet they are closely correlated, have reasonable agreement in detecting increased arterial stiffness and give similar associations with carotid stiffness and atherosclerosis.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement