Related Experiment Video
Updated: Dec 12, 2025

Investigations on the GaIII Complex of EOB-DTPA and Its 68Ga Radiolabeled Analogue
Published on: August 17, 2016
Bismuth chelate as a contrast agent for X-ray computed tomography
Ji-Jun Fu1,2, Jun-Jie Guo3,4, Ai-Ping Qin5
1The Fifth Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, Guangzhou, 510700, Guangdong, China. fujj@gzhmu.edu.cn.
A novel bismuth-based contrast agent offers improved kidney imaging in CT scans with minimal toxicity and rapid clearance. This cost-effective agent shows promise for safer clinical applications compared to traditional iodinated agents.
Area of Science:
- Radiology and Imaging
- Nanomedicine
- Biomaterials
Background:
- Iodinated contrast agents for X-ray computed tomography (CT) imaging can cause adverse side effects, necessitating the development of novel alternatives.
- Heavy metal nanoparticles (e.g., gold, bismuth) offer advantages like long circulation and tumor targeting but may present toxicity and complex preparation challenges.
Purpose of the Study:
- To investigate a small molecular bismuth chelate as a potential CT contrast agent.
- To evaluate the efficacy, safety, and pharmacokinetic profile of the novel bismuth agent.
Main Methods:
- Synthesis of a small molecular bismuth chelate using diethylenetriaminepentaacetic acid (DPTA).
- Evaluation of CT imaging performance for the kidney compared to iohexol.
- In vitro cytotoxicity assays on L02 cells and hemolysis tests.
- In vivo toxicity assessment in mice via repeated high-dose intravenous administration.
- Pharmacokinetic studies to determine elimination kinetics and half-life.
Main Results:
- The bismuth agent demonstrated superior CT imaging enhancement in the kidney compared to iohexol, indicated by improved CT values.
- Negligible toxicity was observed in L02 cells and minimal hemolysis up to 500 µM.
- No detectable organ morphology changes occurred in mice after high-dose repeated administration.
- The agent exhibited first-order elimination kinetics with a short half-life of 0.602 h, indicating rapid clearance and good biocompatibility.
Conclusions:
- The developed bismuth agent is easily prepared, cost-effective, and exhibits excellent biocompatibility.
- Its superior imaging performance and safety profile suggest it is a strong candidate for novel CT contrast agents in clinical settings.
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT

