A Novel Approach for the Administration of Medications and Fluids in Emergency Scenarios and Settings
Published on: November 9, 2016
The Efficacy, Safety, and Convenience of a New Device for Flushing Intravenous Catheters (Baro Flush™): A Prospective
Youn I Choi1, Jae Hee Cho1, Jun-Won Chung1
1Department of Gastroenterology, Gil Medical Center, Gachon University, Incheon 21565, Korea.
Abstract:
Background and Objectives: An effective flushing technique is essential to reduce intravenous (IV)-related complications and improve patient care. New technology should contribute to such improvements, while reducing costs and increasing care efficiency. This study evaluated the efficacy, safety, and convenience of a new flushing technique using a Baro Flush™ controller. Materials and Methods: We evaluated the efficacy and safety of Baro Flush™ by measuring the infusion flushing volume and pressure in vitro. Afterwards, we prospectively enrolled 3000 patients with flushing and assigned 1500 patients with a new technique for flushing and 1500 with a conventional flushing method, which was performed by 48 registered nurses (RNs) at the Gil Medical Center in June 2018. The efficacy, safety, and convenience of the new flushing method were evaluated though a questionnaire survey. Results: The average flushing pressure was 12.5 ± 0.6 psi (86.18 ± 4.14 kPa) with 1.2 ± 0.2 mL per flush, as recommended by the Centers for Disease Control and Prevention based on 85 experiments. No IV-catheter-related complications were reported by the RNs during the study. More than 80% of the RNs reported that the new flushing method was easier to learn, improved care efficacy, and was more convenient than conventional flushing. Conclusions: The new flushing method using a Baro Flush™ controller showed improved efficacy, safety, and convenience compared with the conventional flushing method, and no IV-catheter-related complications occurred, including occlusion and inflammation. The new flushing method promises to reduce IV-catheter-related complications and shows improved efficacy, safety, and convenience.
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Imaging Studies VII: Vascular Imaging
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview