Use of routine computed tomography scans for detecting osteoporosis in thoracolumbar vertebral bodies
Ping Wang1, Wei She2, Zeqing Mao1
1Department of Radiology, Gansu Provincial Hospital, No.204, Donggang West Street, Chengguan District, Lanzhou, 730000, Gansu, China.
Objective:
This study observed the distribution of CT attenuation values for T10-L3 vertebral bodies and derived the Hounsfield unit (HU) thresholds using the quantitative computed tomography (QCT) as a reference to predict osteoporosis and normal bone density.
Methods:
We included 482 subjects who were scheduled to undergo CT lung cancer screening and pulmonary nodule follow-up from May 2015 to February 2019. The subjects were scanned with the calibration phantom beneath the back while performing a chest CT scan. The volumetric bone mineral density (vBMD) and CT attenuation values of T10-L3 vertebral bodies were measured, and the correlation between the two measurements was analyzed. Receiver operator characteristic (ROC) curves were generated to determine diagnostic optimal thresholds.
Results:
A total of 2716 vertebral bodies of 457 participants were measured after exclusion screening. CT attenuation value of each plane's vertebral body showed a strong correlation with vBMD. The optimal threshold of > 141 HU was 93.5% sensitive and 86.1% specific for the recognition of normal BMD. The optimal threshold of < 102.4 HU was 96.9% specific and 82.1% sensitive for distinguishing osteoporosis from osteopenia and normal BMD. The average CT attenuation values of vertebral bodies with compressed and normal morphology were 108.9 ± 20.6 and 136.8 ± 32.2 HU, respectively.
Conclusion:
Sagittal reconstruction of the thoracic vertebrae using routine thoracic CT image combined with CT attenuation value measurements of the spine is valuable for predicting bone mineral density in high-risk populations. The mean CT attenuation values of the vertebral bodies with vertebral compression appearance were lower than that of normal vertebral shape.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT