Outcomes of press-fit radial head arthroplasty following complex radial head fractures
Luis Lobo-Escolar1, César Abellán-Miralles2, Anna Escolà-Benet3
1Department of Orthopaedics & Traumatology Surgery, Hospital Asepeyo Sant Cugat, Sant Cugat, Barcelona, Spain; Autonomous University of Barcelona, Barcelona, Spain.
Introduction:
Press-fit radial head arthroplasty (RHA) is increasingly popular in treating complex radial head fractures. This study assessed the outcome of RHA, including the outcome following re-operation, and explored potentially influencing factors.
Hypothesis:
Complex radial head fractures treated with press-fit radial head prosthesis would have a favourable outcome.
Material And Methods:
Data on all consecutive patients treated with anatomic press-fit RHA from February 2002 to February 2015 were analysed. Post-surgery clinical and X-rays assessments included a post-discharge evaluation of function. Standardised methods implemented include the assessment of range of motion (ROM), the Mayo Elbow Performance Score (MEPS) and subjective satisfaction scales.
Results:
Forty-five patients were recruited and 71% were classified in Mason IV and 62.2% had the "terrible triad". Re-operation was performed in 26.7% and prosthesis removal in 15.6%. Mean follow-up was 140.8 months (95% CI 117.7-164) and prosthesis survival was 69.5% at 24 months. Mean MEPS before re-operations was 86.3±15.9. Pain and/or instability were the most common reasons for re-operation, and re-operations were significantly more frequent in patients having one or more "associated injuries" (p=0.05), but not the terrible triad; and in patients with radiological "loosening" signs (p<0.01). Subjective scores were relatively good in most patients, although the functionality perceived in the re-operation with implant removal group was rather low.
Discussion:
Several studies of complex radial head fractures treated with press-fit radial head prosthesis have also shown favourable results, but the patients in such studies generally had less severe lesions. Moreover, differently from previous reports, this study with a long follow-up has included a younger population with high functionality requirements. Pain and/or instability, as observed in several previous reports, were the most common reasons for re-operation, but contrary to the expectation, the terrible triad was not associated with unfavourable outcome.
Conclusion:
Treatment of complex fractures with press-fit radial head prosthesis, including re-operation with implant removal yields satisfactory results. Most scores of functional and subjective outcome improved following the re-intervention and most patients returned to their usual occupation.
Level Of Evidence:
Level IV; case series; treatment study.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...