Lipid Analysis on Block Copolymer-containing Packaging Solution and Lens Care Regimens: A Randomized Clinical Trial
Amanda Shows1, Rachel L Redfern2, Wolfgang Sickenberger3
1Alcon Research, LLC, Fort Worth, Texas.
New lotrafilcon B contact lenses with EOBO solutions show significantly lower cholesterol extraction compared to other silicone hydrogel lenses. This finding suggests improved lens care for contact lens wearers using these advanced materials.
Area of Science:
- Ophthalmology
- Biomaterials Science
- Contact Lens Technology
Background:
- Silicone hydrogel contact lenses are widely used but can interact with biological molecules.
- Cholesterol accumulation on contact lenses may influence lens performance and wearer comfort.
- Understanding lipid sorption is crucial for developing advanced contact lens materials and care solutions.
Purpose of the Study:
- To compare cholesterol extraction from lotrafilcon B lenses with EOBO solutions against habitual silicone hydrogel lenses using non-EOBO multipurpose solutions (MPS).
- To evaluate the efficacy of EOBO-containing lens care solutions in minimizing cholesterol uptake by contact lenses.
Main Methods:
- A prospective, randomized, observer-masked parallel study involving habitual wearers of senofilcon C, senofilcon A, comfilcon A, and samfilcon A lenses.
- Participants were randomized to either lotrafilcon B lenses with EOBO solutions (OPTI-FREE PUREMOIST or CLEAR CARE PLUS with HydraGlyde) or their habitual lenses and MPS.
- Cholesterol extraction was measured using a fluorometric enzymatic assay on a subset of collected lenses.
Main Results:
- Lotrafilcon B lenses with EOBO solutions demonstrated significantly lower mean cholesterol extraction (0.28 ± 0.18 μg/lens and 0.28 ± 0.48 μg/lens) compared to habitual lenses (ranging from 2.07 to 4.18 μg/lens).
- The differences in cholesterol extraction were statistically significant (P < .0001) for all comparisons.
- Analysis included 143 lenses, with 95 from habitual lens wearers and 48 from lotrafilcon B + EOBO lens wearers.
Conclusions:
- Cholesterol sorption is significantly reduced in lotrafilcon B lenses when cared for with polyoxyethylene-polyoxybutylene (EOBO)-containing solutions.
- This suggests that EOBO-based solutions offer an advantage in managing lipid deposition on contact lenses.
- The findings support the use of lotrafilcon B lenses with EOBO solutions for potentially improved contact lens hygiene and performance.