Imaging and Quantification of the Hepatic Vasculature of Mice Using Ultrafast Doppler Ultrasound
Published on: July 19, 2024
Diagnosis of liver tumors by multimodal ultrasound imaging
Jia Hu1, Zhi-Yu Zhou2, Hong-Ling Ran1
1Department of Medical Ultrasound, The First Affiliated Hospital of Nanchang University.
Abstract:
To investigate the diagnostic value of multimodal ultrasound imaging composed of conventional ultrasonography (US), contrast-enhanced ultrasonography (CEUS), and shear wave elastography (SWE) for liver tumors.Between October 2017 and October 2019, US, CEUS, and SWE examinations of a total of 158 liver tumors in 136 patients at The First Affiliated Hospital of Nanchang University were performed. The histopathological or imaging diagnostic results were used as controls to evaluate the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of US, CEUS, SWE, and multimodal ultrasound imaging, which combines these 3 modes, in the differential diagnosis of benign and malignant liver tumors.Among the 158 tumors, there were 64 benign tumors, including 55 cases of hepatic hemangioma, 3 cases of focal nodular hyperplasia of the liver, 4 cases of hepatic cyst, and 2 cases of focal nonuniform distribution of fat in the liver. There were 94 malignant tumors, including 32 cases of hepatocellular carcinoma, 22 cases of intrahepatic cholangiocellular carcinoma, 29 cases of metastatic liver cancer, and 11 cases of dysplastic nodules in cirrhotic liver. In the diagnosis of benign and malignant liver tumors, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 82.56%, 68.06%, 75.96%, 75.53%, and 76.56% for US; 92.39%, 86.36%, 89.87%, 90.43%, and 89.06% for CEUS; 87.14%, 76.81%, 82.91%, 82.98%, and 82.81% for SWE; and 97.85%, 95.38%, 96.83%, 96.81%, and 96.88% for multimodal ultrasound imaging, respectively. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were all significantly higher for multimodal ultrasound imaging than those values for US, CEUS, and SWE (all P < .05). The areas under the receiver operating characteristic curve for US, CEUS, SWE, and multimodal ultrasound imaging in the diagnosis of benign and malignant liver tumors were 0.760, 0.897, 0.829, and 0.968, respectively.US, CEUS, and SWE all have diagnostic value in the diagnosis of benign and malignant liver tumors. Multimodal ultrasound imaging could significantly increase the accuracy of the diagnosis of benign and malignant liver tumors and has higher value for clinical application.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
06:39Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor
Published on: May 23, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...