Related Experiment Video
Updated: Dec 12, 2025

Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
Published on: May 12, 2017
Repolarization instability and arrhythmia by IKr block in single human-induced pluripotent stem cell-derived
Cristina Altrocchi1, Tessa de Korte2,3, Joyce Bernardi1
1Department of Cardiology, CARIM, Maastricht University Medical Center+, PO Box 5800, 6202 AZ Maastricht, The Netherlands.
Aims:
Human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) have proven valuable for studies in drug discovery and safety, although limitations regarding their structural and electrophysiological characteristics persist. In this study, we investigated the electrophysiological properties of Pluricyte® CMs, a commercially available hiPSC-CMs line with a ventricular phenotype, and assessed arrhythmia incidence by IKr block at the single-cell and 2D monolayer level.
Methods And Results:
Action potentials were measured at different pacing frequencies, using dynamic clamp. Through voltage-clamp experiments, we determined the properties of INa, IKr, and ICaL. Intracellular Ca2+ measurements included Ca2+-transients at baseline and during caffeine perfusion. Effects of IKr block were assessed in single hiPSC-CMs and 2D monolayers (multi-electrode arrays). Action-potential duration (APD) and its rate dependence in Pluricyte® CMs were comparable to those reported for native human CMs. INa, IKr, and ICaL revealed amplitudes, kinetics, and voltage dependence of activation/inactivation similar to other hiPSC-CM lines and, to some extent, to native CMs. Near-physiological Ca2+-induced Ca2+ release, response to caffeine and excitation-contraction coupling gain characterized the cellular Ca2+-handling. Dofetilide prolonged the APD and field-potential duration, and induced early afterdepolarizations. Beat-to-beat variability of repolarization duration increased significantly before the first arrhythmic events in single Pluricyte® CMs and 2D monolayers, and predicted pending arrhythmias better than action-potential prolongation.
Conclusion:
Taking their ion-current characteristics and Ca2+ handling into account, Pluricyte® CMs are suitable for in vitro studies on action potentials and field potentials. Beat-to-beat variability of repolarization duration proved useful to evaluate the dynamics of repolarization instability and demonstrated its significance as proarrhythmic marker in hiPSC-CMs during IKr block.
More Related Videos
08:53Human iPSC-Derived Cardiomyocyte Networks on Multiwell Micro-electrode Arrays for Recurrent Action Potential Recordings
Published on: July 15, 2019
10:30Technical Applications of Microelectrode Array and Patch Clamp Recordings on Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes
Published on: August 4, 2022